Powered by
mideas
Podpora: +386 40 771 779
  • DOMOV
  • ULTRAZVOČNI APARATI
    • BREZŽIČNA ULTRAZVOČNA SONDA
    • KARDIOVASKULAR
    • GENERAL IMAGING
    • POINT-OF-CARE
    • GINEKOLOGIJA IN PORODNIŠTVO
    • VETERINA - PIEMEDICAL
    • 4 PAMETNI KORAKI DO UZ
    • OBNOVLJENI UZ in MR
    • SERVIS >
      • SERVIS
      • SERVIS SOND
      • UPS-brezprekinitveno napajanje za UZ aparate
  • MAGNETNE RESONANCE
    • 7 razlogov za ODPRTI MR sistem
    • MR - Video predstavitev
    • MR - Tehnologija
    • MR - Ekonomika
    • MR - Sistemi
    • MR - Slike
  • FINANCIRANJE
    • Najem medicinske opreme
  • IZOBRAŽEVANJE
    • Delavnica SWE Ultrazvoka
    • MY LIBRARY
    • ePOS ECR >
      • ePOS 2017
      • ePOS 2016
    • WEBINAR
    • ESAOTE
    • BLOG
  • KONTAKT
    • VPRAŠAJTE NAS
    • PROSTA DELOVNA MESTA

10 koristnih nasvetov za optimizacijo Echo UZ slike

15/5/2014

 
Pridobivanje dobre kakovosti kardio (echo) slike je še posebno pomembno pri kritično bolnih pacientih. Podajam nekaj ​​nasvetov za optimizacijo ehokardiografske slike:
Picture
MyLab Seven eHD CrystaLine - TEE probe image
1. Optimizirajte položaj bolnika. Levi stranski položaj, z levo roko nad glavo, je najboljši.
Picture
Položaj pacient za apikalni pristop
2. Zatemnite sobo, kadar je to mogoče. To bo sprostilo bolnika in morda tudi vas. :)

3. Če so parasternalna in apikalna okna omejena (položaj telesa, kirurška oblačila, itd ) je subkostalni pogled lahko edino dostopno okno .

4. Pridobite sliko izven osi, saj s tem povečate vidnost specifičnih struktur.

5. Pridobite sliko pri končnem poteku, ko je srce bližje sondi.

6. Izogibajte se krajšanju LV apeksa. Včasih je apeks nižje in bolj lateralno, kot je pričakovano.

7. M-mode je koristno orodje za natančno časovno razporeditev srčnih dogodkov; npr. RV ali RA kolaps pri določanju morebitne tamponade srca. M-mode je pravtako zelo uporaben za določanje respiratornih variacij velikosti spodnje vene cave ( IVC ); npr. za oceno volumna odzivnosti (glej sliko).

8. Najprej ojačamo Gain do najvišje točke in ga nato prilagodimo navzdol, da dobimo optimalno svetlost slike. Gain namreč prilagodi amplitudo sprejetih signalov  po celotni dolžini ultrazvočnega snopa .

9. Nastavite TGC (time gain compensation) v srednjem območju z nižjim Gain-om v bližnjem polju in višjim Gain-om v daljšem polju. To bo nadomestilo dušenje snopa z naraščajočo razdaljo opazovane strukture od pretvornika (sonde).Novejši ultrazvočni aparati imajo možnost samodejnega prilagajanja Gain-a v celotni sliki .
Picture
10. Uporabite globino (depth),  ki ustrezno prikaže celotno področje interesa. Z drugimi besedami; prilagodite globino področja tako, da je območje interesa v sredini zaslona.

Comments are closed.

    Avtor

    Mitja Dobovičnik

    View my profile on LinkedIn

    Arhiv

    December 2022
    February 2022
    November 2021
    October 2021
    September 2021
    August 2021
    July 2021
    June 2021
    May 2021
    November 2020
    October 2020
    May 2020
    March 2020
    December 2019
    August 2019
    March 2019
    October 2018
    August 2018
    May 2018
    February 2018
    January 2018
    November 2017
    October 2017
    September 2017
    June 2017
    May 2017
    March 2017
    February 2017
    January 2017
    November 2016
    September 2016
    August 2016
    May 2016
    March 2016
    February 2016
    January 2016
    December 2015
    November 2015
    October 2015
    September 2015
    July 2015
    June 2015
    May 2015
    April 2015
    March 2015
    February 2015
    January 2015
    December 2014
    November 2014
    October 2014
    September 2014
    July 2014
    June 2014
    May 2014
    April 2014
    March 2014
    February 2014
    January 2014
    December 2013
    November 2013
    October 2013
    September 2013

    Kategorije

    All
    Dogodki
    Edukacija
    E Novice
    E-novice
    MR
    Novosti
    Servis Sonde
    Tehnologija
    Testiranje Aparat
    White Paper

    RSS Feed

9
Kontakt

Mideas d.o.o.
Osebna izkaznica

t: +386 (0)40 77 17 79
e:info@mideas.si
Mideas © 2019
Ultrazvočni aparati

MyLab9 eXP
MyLab X8
MyLab X7
MyLab X6
MyLab X5
MyLab Omega
Magnetne resonance

Magnetne resonance
Video predstavitev
Tehnologija
Ekonomika
MR sistemi
MR slike
Servisne storitve

Servis ultrazvočnih aparatov
Servis magnetnih resonanc
Servis ultrazvočnih sond


Povezava
Blog


Powered by Create your own unique website with customizable templates.